jueves, 15 de diciembre de 2016

Liquid line filter-drier & Head exchanger



Liquid line filter-drier

On all transport refrigeration systems, because of the uncertainties of installation and service, a liquid line filter-drier is essential. It is recommended that the filter-drier be aversized by at least 50% for the refrigerant charge because of the many opportunities during field maintenance for moisture to enter the system. It should have flare connections for easy replacement.

Head exchanger



A heat excharger should be considered mandatory on all units. It improves the performance, insures liquid refrigerant at the expansion valve, and helps assure the return of dry gas. Normally it should be located inside the refrigeranted space to avoid loss of capacity, but it can be located externally if insulated.

No hay comentarios:

Publicar un comentario